100KW 600VDC-380VAC Hydrogen Inverter
Driven by global carbon neutrality goals, hydrogen energy—as a zero-carbon energy carrier—is accelerating its transition from industrial deployment to large-scale application. Among these developments, hydrogen inverters, serving as the “heart” of hydrogen fuel cell power generation systems, have become a critical link for integrating hydrogen energy into sectors like the power grid, transportation, and industry through efficient DC-to-AC conversion technology. Recently, multiple companies have achieved breakthroughs in hydrogen inverter technology, propelling the clean energy transition forward.

|
Model |
BZP-100KW |
|
|
Isolation mode |
Low Frequency Transformer |
|
|
DC Input |
Rated voltage (Vdc) |
600V |
|
Rated current(A) |
166A |
|
|
AC Output |
Rated output power |
100KW |
|
Output waveform |
Pure Sine Wave |
|
|
Rated Voltage |
380VAC±3% |
|
|
Phases |
3 phase 4 wire |
|
|
Rated current(A) |
152A (phase current) |
|
|
Frequency |
50Hz or 60Hz |
|
|
Rated output voltage range (V) |
380/400/415/440VAC optional |
|
|
Power Factor(PF) |
1 |
|
|
Overload Ability |
150%, 5 seconds |
|
|
Efficiency |
>92% |
|
|
Waveform distortion rate (THD) |
<3%(Linear load) |
|
|
Dynamic Response (0 to 100% load) |
5%,≤50ms |
|
|
Display |
LCD |
|
|
Running mode |
Working continuously |
|
|
Electrical insulation properties |
2000Vac, 1 Minute |
|
|
Communication interface (optional) |
RS485 |
|
|
Protection Function |
Protection |
Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. |
|
Cooling method |
Fan-cooled |
|
|
Short-circuit protection |
No automatic recovery, need to restart the machine |
|
|
Working environment |
Noise ( 1 meter) |
≤100dB |
|
Degree of protection |
IP20(indoor) |
|
|
Working Altitude(m) |
≤2000 |
|
|
Working temperature |
-25~+55℃ |
|
|
relative humidity |
0~90%,non-condensing |
|