3 Phase Intelligent AC-DC Power Converter
Product Features
1,Wide range of constant power voltage: 300Vdc~1000Vdc constant power output;
2,Strong low-voltage load capacity: 50V high-current output to meet the needs of low-voltage vehicle charging;
3,High efficiency: high efficiency operation in the full load range;
4,Ultra-low standby power consumption: <12W, support sleep mode;
5,Isolated air ducts filling design: good heat dissipation, high reliability;
6,Built-in intelligent discharge circuit: automatic discharge residual charge, high system reliability;
7,Battery anti-reverse flooding: effective protection of the battery, while ensuring the reliable operation of the system;
8,Full digital control: dual DSP design, high reliability control;
9,Non-destructive hot-swap: high reliability control High system reliability; Non-destructive hot-plugging: plug-and-play, convenient maintenance;
10,Wide range of input voltage: 260Vac ~ 530Vac, adapting to a variety of power grids;
11,Wide range of output voltage: 50Vdc~1000Vdc, adapted to all kinds of power batteries and storage batteries;
12,Wide temperature range: -40℃~+75℃;
13,Adapt to a variety of scenarios: public charging piles, optical storage supercharging system, heavy trucks charging and switching equipment, charging piles for seaside applications; etc.
|
Model
|
BEG75020S-21kw
|
BEG75040-75kw
|
BEG75050-400kw
|
||
|
AC Input
|
|||||
|
Input voltage
|
90~280Vac
|
260~530Vac
|
260~530Vac
|
||
|
Max. input current
|
<96A
|
<150A
|
<740A
|
||
|
Input frequency
|
55±10Hz
|
||||
|
Power factor
|
≥ 0.99
|
||||
|
Efficiency(fully loaded)
|
>95%
|
||||
|
THD
|
<5%
|
||||
|
DC Output
|
|||||
|
Rated output
|
21kW
|
75kW
|
400kW
|
||
|
Output voltage range
|
50~750Vdc
|
50~750Vdc
|
50~750Vdc
|
||
|
Constant power voltage range
|
350~750Vdc
|
400~750Vdc
|
400~750Vdc
|
||
|
Output current range
|
0~60A
|
0~187.5A
|
0~1000A
|
||
|
Output current limiting
|
0.1-60A
|
0.1-187.5A
|
0.2-1000A
|
||
|
Current sharing
|
Imbalance<±5%
|
||||
|
Voltage stabilized accuracy
|
≤±0.5%
|
||||
|
Current stabilized accuracy
|
≤±1%
|
||||
|
Monitor
|
|||||
|
Communication
|
CAN
|
||||
|
Indicator light
|
Green: Normal operation Yellow: Protection alarm Red: Fault alarm
|
||||
|
Operating Environment
|
|||||
|
Operating temperature
|
-40ºC~+75ºC,derates from +55ºC
|
||||
|
Storage temperature
|
-40ºC~+80ºC
|
||||
|
Humidity
|
≤95%RH, without condensation
|
||||
|
Cooling
|
Fan cooling
|
||||
|
Altitude
|
2000m, Above 2000m, derating needs to be considered
|
||||
|
Alarm and Protection
|
|||||
|
Entered Undervoltage protection
|
Automatic shutdown protection, automatic resumption of work after normal input
|
||||
|
Output overvoltage protection
|
Automatically shuts down and locks, and needs to be re-powered on to resume work
|
||||
|
Over-current and short-circuit protection
|
Automatically shuts down and locks, and needs to be re-powered on to resume work
|
||||
|
Over-temperature protection
|
Automatic shutdown protection, automatic resumption of work after normal temperature
|
||||