48VDC-380VAC 3 phase 20KW low frequency power inverter
Input Characteristics: Rated DC input voltage of 48V, supporting an ultra-wide voltage range (e.g., 42V-100V or customised range), capable of adapting to extremely low voltage scenarios as low as 42V, ensuring stable output even under battery under-voltage conditions.
Output Characteristics: Rated output power 20kW, output voltage 380VAC (three-phase), frequency adjustable 50Hz/60Hz, pure sine wave output (THD ≤3% for linear loads), dynamic response time ≤50ms, power factor ≥0.99, efficiency ≥88%.
Line-frequency transformer: Utilises a line-frequency isolation transformer to achieve complete AC/DC isolation, effectively suppressing harmonic interference and enhancing system surge resistance. Supports inductive loads such as motors and water pumps (e.g., automatic recovery after 10 seconds at 115% overload).
Ultra-low voltage input capability: Through wide voltage input design (e.g., 42V-100V) and intelligent boost technology, it ensures full power output even during deep battery discharge or fluctuating PV input, preventing shutdowns caused by insufficient voltage.
Anti-interference design:
Electromagnetic compatibility (EMC) design: Shielded enclosure and optimised grounding, certified to CE (EMC/LVD) standards, meeting industrial-grade anti-interference requirements.
Dynamic Current-Loop Control with SVPWM Algorithm: Reduces switching noise and suppresses harmonic distortion to ensure pristine output waveforms.
Multi-Layer Protection Mechanisms: Input over/under-voltage, output overload/short-circuit, overtemperature, fan failure, and lightning protection. Supports RS485/CAN communication interfaces for remote monitoring.
High reliability and durability: Utilises IPM smart modules (e.g., Mitsubishi 6th generation IPM) and power frequency topology, supporting operation across -25°C to 50°C with altitudes ≤3000m (derating required). Service life extends to 15 years. Modular design facilitates maintenance.
|
Model |
BZP-20KW |
|||
|
Isolation mode |
Low Frequency Transformer |
|||
|
DC Input |
Rated voltage (Vdc) |
48V |
||
|
Rated current(A) |
416A |
|||
|
AC Output |
Rated output power |
20KW |
||
|
Output waveform |
Pure Sine Wave |
|||
|
Rated Voltage |
220V±3% |
380VAC±3% |
||
|
Phases |
Single phase |
3 phase 4 wire |
||
|
Rated current(A) |
90.9A |
30A (phase current) |
||
|
Frequency |
50Hz or 60Hz |
|||
|
Power Factor(PF) |
0.9 |
|||
|
Overload Ability |
120%, 35 seconds |
|||
|
Efficiency |
>88% |
|||
|
Waveform distortion rate (THD) |
<3%(Linear load) |
|||
|
Dynamic Response (0 to 100% load) |
5%,≤50ms |
|||
|
Display |
LCD |
|||
|
Running mode |
Working continuously |
|||
|
Electrical insulation properties |
2000Vac, 1 Minute |
|||
|
Communication interface (optional) |
RS485 |
|||
|
Protection Function |
Protection |
Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. |
||
|
Cooling method |
Fan-cooled |
|||
|
Short-circuit protection |
No automatic recovery, need to restart the machine |
|||
|
Working environment |
Noise ( 1 meter) |
≤50dB |
||
|
Degree of protection |
IP20(indoor) |
|||
|
Working Altitude(m) |
≤2000 |
|||
|
Working temperature |
-25~+55℃ |
|||
|
relative humidity |
0~90%,non-condensing |
|||
|
Mechanical dimension |
Depth* Width * Height |
550x550x860mm |
||
|
Weight (Kg) |
186Kg |