Leave Your Message
IP54 outdoor 200KW 3 phase battery charger

LCD Smart Series

Products Categories
Featured Products

IP54 outdoor 200KW 3 phase battery charger

Bangzhao Electric's IP54 outdoor 200KW 3 phase battery charger is a high power supply unit designed for industrial applications. It adopts three-phase power supply mode, which can provide stable and powerful power output to meet the stringent power requirements of large-scale industrial equipment and production lines. It has high efficiency power conversion capability, which can reduce energy loss. 

    Product Features

    Superior Power Output Capability
    Voltage Range: Constant power output spanning 300Vdc-1000Vdc, supporting high-current loads down to 50V. Compatible with various power and energy storage batteries.
    Charging Efficiency: Maintains high efficiency across the entire load range for maximized energy utilization. Low standby power consumption <12W, with sleep mode for further energy savings.

    Extreme Environment Adaptability
    Wide Temperature Operation: Stable performance from -40°C to +75°C, suitable for extreme cold, intense heat, and high-altitude regions.
    Grid Compatibility: Input voltage supports 260Vac-530Vac, adapting to global grid standards.
    Protection Rating: IP54-rated for splash-proof and dust-proof performance, withstanding harsh outdoor weather.

    Reliable Structural Design
    Heat Dissipation System: Encapsulated air duct design enhances thermal efficiency and extends equipment lifespan.
    Hot-Swap Functionality: Supports damage-free hot-swapping for simplified maintenance and upgrades, reducing operational costs.

    IP54 battery charger.jpg

    Category

    Name

    Parameter

    Environmental conditions

    Operation temperature

    -40°C ~ +75°C, derating is require when the temperature is above 55°C.

    Storage temperature

    -40°C ~ +70°C

    Relative humidity

    ≤95%RH, without condensation

    Cooling mode

    Forced air cooling

    Altitude

    2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.

    Atmospheric pressure

    79 kPa ~ 106 kPa

    AC input

    Input system

    Three phases + PE

    Rated voltage

    380 Vac

    Voltage range

    260 Vac ~530Vac

    Maximum current

    400A

    Rated frequency

    50Hz/60Hz

    DC output

    Voltage range

    50~1000V

    Current range

    1~665A

    Rated current

    665A@300V (required for setting of current limiting point,1000V is 200A)

    Steady voltage precision

    <±0.5%

    Steady current precision

    ≤±1% (rated range of 20% ~ 100% for output load)

    Load regulation rate

    ≤±0.5%

    Startup overshoot

    ≤±3%

    Peak-to-peak value noise

    ≤1% (150~1000V, 0~20MHz)

    Power factor and THD

    Power factor

    ≥0.95   Full-load output power of @25%~50%

    ≥0.98   Full-load output power of @50%~100%

    ≥0.99  Full-load output power, input nominal voltage and frequency of @100%

    THD

    ≤5%  Full-load output power of  @50%~100%

    Efficiency

    Under Rated input voltage

    ≥95%,@1000V,full load